more on event topic for less cloud usage
This commit is contained in:
@@ -10,6 +10,28 @@ import os
|
||||
import logging
|
||||
import sys
|
||||
|
||||
# from 1 to 5 (Modbus)
|
||||
# PCS
|
||||
# AC_Resistance
|
||||
# DC_Resistance
|
||||
# Hz
|
||||
# DCV
|
||||
# VL1L2
|
||||
# VL2L3
|
||||
# VL3L1
|
||||
|
||||
# OnEvent
|
||||
# ACSw_Status
|
||||
# ActErrNoX
|
||||
# DCSw_3_Status
|
||||
# Fault_Id_tmp
|
||||
# Fault_Status
|
||||
# InvSt_tmp
|
||||
# MV_Transformer_Gas_Monitoring
|
||||
# MV_Transformer_Oil_Level_Trip
|
||||
# MV_Transformer_Pressure
|
||||
# MV_Transformer_Pressure_Trip
|
||||
|
||||
def generate_oe(device_id, modbus_tags):
|
||||
return {
|
||||
'description': '',
|
||||
@@ -112,7 +134,6 @@ for device in devices:
|
||||
current_device_modules = registry_manager.get_modules(device.deviceId)
|
||||
for module in current_device_modules:
|
||||
if (module.module_id == module_id):
|
||||
#print(f"{module.module_id}")
|
||||
device.setModule(module)
|
||||
payload = '{"method":"GET", "path":"/azure-iotedge/messages"}'
|
||||
try:
|
||||
@@ -120,7 +141,6 @@ for device in devices:
|
||||
response = registry_manager.invoke_device_module_method(device_id=device.deviceId, module_id=module_id, direct_method_request=direct_method)
|
||||
device_messages = json.dumps(response.payload, indent = 2)
|
||||
parsed_messages = json.loads(device_messages)
|
||||
#print("Parsed messages")
|
||||
message_ids_with_tags = {}
|
||||
tags_to_on_event = defaultdict(set)
|
||||
for message in parsed_messages["data"]:
|
||||
@@ -131,6 +151,7 @@ for device in devices:
|
||||
|
||||
tags = message.get("tags", {}).get("modbus_tcp_master", {})
|
||||
|
||||
# This block seems list existing OE topics and their content.
|
||||
for asset, tag_list in tags.items():
|
||||
if "InvSt" in tag_list and "OE" in topic_name:
|
||||
message_ids_with_tags.setdefault(message_id, message)
|
||||
@@ -140,68 +161,69 @@ for device in devices:
|
||||
message_ids_with_tags.setdefault(message_id, message)
|
||||
tags_to_on_event[asset].add("Fault_Id")
|
||||
print(f"{device.getDeviceId()} {device.getSite()} {device.getNumber()} {message_id} {topic_name} {asset} Fault_Id")
|
||||
# print(f"{device.getDeviceId()} {device.getSite()} {device.getNumber()}")
|
||||
# print(f"Messages to update: {', '.join(str(key) for key in message_ids_with_tags.keys())}")
|
||||
# for asset, tag in tags_to_on_event.items():
|
||||
# print(f"Alarms to make on event:")
|
||||
# print(f"{asset}: {', '.join(tag)}")
|
||||
# print(f"Finishing on {device}")
|
||||
|
||||
# oe_exists = False
|
||||
# twelve_exists = False
|
||||
print(f"{device.getDeviceId()} {device.getSite()} {device.getNumber()}")
|
||||
print(f"Messages to update: {', '.join(str(key) for key in message_ids_with_tags.keys())}")
|
||||
for asset, tag in tags_to_on_event.items():
|
||||
print(f"Alarms to make on event:")
|
||||
print(f"{asset}: {', '.join(tag)}")
|
||||
print(f"Finishing on {device}")
|
||||
|
||||
# for message in message_ids_with_tags.values():
|
||||
# if message['outputTopic'] == "REL_OE_PCS":
|
||||
# oe_exists = True
|
||||
# if message['outputTopic'] == "REL_OE_PCS_12H":
|
||||
# twelve_exists = True
|
||||
oe_exists = False
|
||||
twelve_exists = False
|
||||
|
||||
# if (oe_exists == False or twelve_exists == False):
|
||||
# first_message = next(iter(message_ids_with_tags.values()))
|
||||
# properties = first_message['properties']
|
||||
# cdid = next((item['value'] for item in properties if item['key'] == 'cdid'))
|
||||
# print(f"{cdid}")
|
||||
for message in message_ids_with_tags.values():
|
||||
if message['outputTopic'] == "REL_OE_PCS":
|
||||
oe_exists = True
|
||||
if message['outputTopic'] == "REL_OE_PCS_12H":
|
||||
twelve_exists = True
|
||||
|
||||
# modbus_tags = {
|
||||
# asset: sorted(list(tags))
|
||||
# for asset, tags in tags_to_on_event.items()
|
||||
# }
|
||||
# new_payload = ""
|
||||
# if (oe_exists == False):
|
||||
# new_payload = '{"method":"POST", "path":"/azure-iotedge/messages", "requestBody":' + json.dumps(generate_oe(cdid, modbus_tags)) + '}'
|
||||
# new_direct_method = CloudToDeviceMethod(method_name=method_name, payload=json.loads(new_payload))
|
||||
# new_response = registry_manager.invoke_device_module_method(device_id=device.deviceId, module_id=module_id, direct_method_request=new_direct_method)
|
||||
# print(json.dumps(new_response.payload, indent = 2))
|
||||
if (oe_exists == False or twelve_exists == False):
|
||||
first_message = next(iter(message_ids_with_tags.values()))
|
||||
properties = first_message['properties']
|
||||
cdid = next((item['value'] for item in properties if item['key'] == 'cdid'))
|
||||
print(f"{cdid}")
|
||||
|
||||
# if (twelve_exists == False):
|
||||
# new_payload = '{"method":"POST", "path":"/azure-iotedge/messages", "requestBody":' + json.dumps(generate_12h(cdid, modbus_tags)) + '}'
|
||||
# new_direct_method = CloudToDeviceMethod(method_name=method_name, payload=json.loads(new_payload))
|
||||
# new_response = registry_manager.invoke_device_module_method(device_id=device.deviceId, module_id=module_id, direct_method_request=new_direct_method)
|
||||
# print(json.dumps(new_response.payload, indent = 2))
|
||||
modbus_tags = {
|
||||
asset: sorted(list(tags))
|
||||
for asset, tags in tags_to_on_event.items()
|
||||
}
|
||||
new_payload = ""
|
||||
if (oe_exists == False):
|
||||
new_payload = '{"method":"POST", "path":"/azure-iotedge/messages", "requestBody":' + json.dumps(generate_oe(cdid, modbus_tags)) + '}'
|
||||
new_direct_method = CloudToDeviceMethod(method_name=method_name, payload=json.loads(new_payload))
|
||||
new_response = registry_manager.invoke_device_module_method(device_id=device.deviceId, module_id=module_id, direct_method_request=new_direct_method)
|
||||
print(json.dumps(new_response.payload, indent = 2))
|
||||
|
||||
# for id, message in message_ids_with_tags.items():
|
||||
# if "OE" in message['outputTopic']:
|
||||
# continue
|
||||
# tags_to_remove = {"InvSt", "Fault_Id"}
|
||||
# for protocol, versions in message['tags'].items():
|
||||
# for version, tag_list in versions.items():
|
||||
# message['tags'][protocol][version] = [
|
||||
# tag for tag in tag_list if tag not in tags_to_remove
|
||||
# ]
|
||||
# print("\n\n\nREMOVING\n\n\n")
|
||||
# new_payload = '{"method":"PUT", "path":"/azure-iotedge/messages/' + str(id) + '", "requestBody":' + json.dumps(message) + '}'
|
||||
# print(new_payload)
|
||||
# new_direct_method = CloudToDeviceMethod(method_name=method_name, payload=json.loads(new_payload))
|
||||
# new_response = registry_manager.invoke_device_module_method(device_id=device.deviceId, module_id=module_id, direct_method_request=new_direct_method)
|
||||
# print(json.dumps(new_response.payload, indent = 2))
|
||||
# print(message['tags'])
|
||||
if (twelve_exists == False):
|
||||
new_payload = '{"method":"POST", "path":"/azure-iotedge/messages", "requestBody":' + json.dumps(generate_12h(cdid, modbus_tags)) + '}'
|
||||
new_direct_method = CloudToDeviceMethod(method_name=method_name, payload=json.loads(new_payload))
|
||||
new_response = registry_manager.invoke_device_module_method(device_id=device.deviceId, module_id=module_id, direct_method_request=new_direct_method)
|
||||
print(json.dumps(new_response.payload, indent = 2))
|
||||
|
||||
for id, message in message_ids_with_tags.items():
|
||||
if "OE" in message['outputTopic']:
|
||||
continue
|
||||
tags_to_remove = {"InvSt", "Fault_Id"}
|
||||
for protocol, versions in message['tags'].items():
|
||||
for version, tag_list in versions.items():
|
||||
message['tags'][protocol][version] = [
|
||||
tag for tag in tag_list if tag not in tags_to_remove
|
||||
]
|
||||
print("\n\n\nREMOVING\n\n\n")
|
||||
new_payload = '{"method":"PUT", "path":"/azure-iotedge/messages/' + str(id) + '", "requestBody":' + json.dumps(message) + '}'
|
||||
print(new_payload)
|
||||
new_direct_method = CloudToDeviceMethod(method_name=method_name, payload=json.loads(new_payload))
|
||||
new_response = registry_manager.invoke_device_module_method(device_id=device.deviceId, module_id=module_id, direct_method_request=new_direct_method)
|
||||
print(json.dumps(new_response.payload, indent = 2))
|
||||
print(message['tags'])
|
||||
|
||||
|
||||
# print("\n\n\nREMOVING\n\n\n")
|
||||
# new_payload = '{"method":"PUT", "path":"/azure-iotedge/messages/' + str(id) + '", "requestBody":' + json.dumps(message) + '}'
|
||||
# print(new_payload)
|
||||
# new_direct_method = CloudToDeviceMethod(method_name=method_name, payload=json.loads(new_payload))
|
||||
# new_response = registry_manager.invoke_device_module_method(device_id=device.deviceId, module_id=module_id, direct_method_request=new_direct_method)
|
||||
# print(json.dumps(new_response.payload, indent = 2))
|
||||
print("\n\n\nREMOVING\n\n\n")
|
||||
new_payload = '{"method":"PUT", "path":"/azure-iotedge/messages/' + str(id) + '", "requestBody":' + json.dumps(message) + '}'
|
||||
print(new_payload)
|
||||
new_direct_method = CloudToDeviceMethod(method_name=method_name, payload=json.loads(new_payload))
|
||||
new_response = registry_manager.invoke_device_module_method(device_id=device.deviceId, module_id=module_id, direct_method_request=new_direct_method)
|
||||
print(json.dumps(new_response.payload, indent = 2))
|
||||
except Exception as e:
|
||||
logger.error(str(e))
|
||||
366
Python/on_event_topics_2.py
Normal file
366
Python/on_event_topics_2.py
Normal file
@@ -0,0 +1,366 @@
|
||||
from azure.iot.hub import IoTHubRegistryManager
|
||||
from azure.iot.hub.protocol.models import QuerySpecification, Module
|
||||
from azure.iot.hub.models import CloudToDeviceMethod, CloudToDeviceMethodResult
|
||||
from dotenv import load_dotenv
|
||||
from isight_device import iSightDevice
|
||||
from collections import defaultdict
|
||||
|
||||
import copy
|
||||
import json
|
||||
import os
|
||||
import logging
|
||||
import sys
|
||||
import re
|
||||
|
||||
# from 1 to 5 (Modbus)
|
||||
# PCS
|
||||
# AC_Resistance
|
||||
# DC_Resistance
|
||||
# Hz
|
||||
# DCV
|
||||
# VL1L2
|
||||
# VL2L3
|
||||
# VL3L1
|
||||
|
||||
def resolve_missing_topic(topic_name, available_list):
|
||||
"""
|
||||
Prompts user to select a topic or create a new one.
|
||||
Returns the selected ID or 0 if creation is requested.
|
||||
"""
|
||||
print(f"Topic {topic_name} not found!")
|
||||
print(f"0. Create a new {topic_name} topic")
|
||||
|
||||
# Display available options
|
||||
for idx, item in enumerate(available_list):
|
||||
print(f"{idx + 1}. {item['outputTopic']}")
|
||||
|
||||
while True:
|
||||
try:
|
||||
choice = int(input(f"Select an option for {topic_name}: "))
|
||||
|
||||
if choice == 0:
|
||||
return 0
|
||||
|
||||
if 1 <= choice <= len(available_list):
|
||||
selected = available_list[choice - 1]
|
||||
return selected['id']
|
||||
|
||||
print("Invalid number, please select from the list.")
|
||||
except ValueError:
|
||||
print("Please enter a valid number.")
|
||||
|
||||
def generate_oe(device_id, modbus_tags):
|
||||
return {
|
||||
'description': '',
|
||||
'outputTopic': 'REL_OE_PCS',
|
||||
'properties': [
|
||||
{'key': 'cdid', 'value': device_id},
|
||||
{'key': 'deviceType', 'value': 'AC_GATEWAY'}
|
||||
],
|
||||
'tags': {
|
||||
'modbus_tcp_master': modbus_tags
|
||||
},
|
||||
'sendOutThreshold': {
|
||||
'mode': 'immediately',
|
||||
'size': 4096,
|
||||
'time': 60,
|
||||
'sizeIdleTimer': {
|
||||
'enable': True,
|
||||
'time': 60
|
||||
}
|
||||
},
|
||||
'minPublishInterval': 0,
|
||||
'samplingMode': 'allChangedValues',
|
||||
'customSamplingRate': False,
|
||||
'pollingInterval': 0,
|
||||
'onChange': True,
|
||||
'enable': True,
|
||||
'format': (
|
||||
'{deviceId:("' + device_id +
|
||||
'"),emissionDate:(now|todateiso8601),deviceType:("AC_GATEWAY"),'
|
||||
'metrics:[{idAsset:(.srcName),name:(.tagName),value:.dataValue,'
|
||||
'timestamp:((.ts/1000000)|todateiso8601)}]}'
|
||||
)
|
||||
}
|
||||
|
||||
def generate_12h(device_id, modbus_tags):
|
||||
return {
|
||||
'description': '',
|
||||
'outputTopic': 'REL_OE_PCS_12H',
|
||||
'properties': [
|
||||
{'key': 'cdid', 'value': device_id},
|
||||
{'key': 'deviceType', 'value': 'AC_GATEWAY'}
|
||||
],
|
||||
'tags': {
|
||||
'modbus_tcp_master': modbus_tags
|
||||
},
|
||||
'sendOutThreshold': {
|
||||
'mode': 'byTime',
|
||||
'size': 4096,
|
||||
'time': 43200,
|
||||
'sizeIdleTimer': {
|
||||
'enable': True,
|
||||
'time': 60
|
||||
}
|
||||
},
|
||||
'minPublishInterval': 0,
|
||||
'samplingMode': 'latestValues',
|
||||
'customSamplingRate': False,
|
||||
'pollingInterval': 43200,
|
||||
'onChange': False,
|
||||
'enable': True,
|
||||
'format': (
|
||||
'{deviceId:("' + device_id +
|
||||
'"),emissionDate:(now|todateiso8601),deviceType:("AC_GATEWAY"),'
|
||||
'metrics:[{idAsset:(.srcName),name:(.tagName),value:.dataValue,'
|
||||
'timestamp:((.ts/1000000)|todateiso8601)}]}'
|
||||
)
|
||||
}
|
||||
|
||||
# Configure logger to use stderr
|
||||
logging.basicConfig(
|
||||
level=logging.ERROR,
|
||||
format='%(asctime)s - %(levelname)s - %(message)s',
|
||||
stream=sys.stderr # <- Key line
|
||||
)
|
||||
logger = logging.getLogger(__name__)
|
||||
|
||||
# .env containing secrets to authorize access to IoT Hub
|
||||
load_dotenv()
|
||||
CONNECTION_STRING = str(os.getenv("CONNECTION_STRING_INOX_PROD"))
|
||||
if CONNECTION_STRING == "":
|
||||
print("Provide a connection string for the Iot Hub before running the script!")
|
||||
exit(13)
|
||||
|
||||
# IoT Edge module and method that allow Moxa AIG-301 management
|
||||
module_id = "thingspro-agent"
|
||||
method_name = "thingspro-api-v1"
|
||||
|
||||
# Connection to IoT Hub and listing of IoT Edge device (so AIG-301 in the scope of SAFT)
|
||||
registry_manager = IoTHubRegistryManager.from_connection_string(CONNECTION_STRING)
|
||||
query_spec = QuerySpecification(query="SELECT * FROM devices WHERE capabilities.iotEdge = true ")
|
||||
query_result = registry_manager.query_iot_hub(query_spec)
|
||||
|
||||
# Sorting devices by site
|
||||
devices = []
|
||||
try:
|
||||
for item in query_result.items:
|
||||
if str(item.connection_state) == "Connected":
|
||||
currentDevice = iSightDevice(str(item.device_id), str(item.tags['site']), int(item.tags['number']), str(item.tags['version']))
|
||||
devices.append(iSightDevice(str(item.device_id), str(item.tags['site']), int(item.tags['number']), str(item.tags['version'])))
|
||||
devices.sort(key = lambda d: (d.site, d.number))
|
||||
else:
|
||||
print(f"Device not connected: {str(item.tags['site'])} {int(item.tags['number'])} {str(item.device_id)}")
|
||||
except KeyboardInterrupt:
|
||||
# This block runs when user presses Ctrl+C
|
||||
print("\nProgram killed by user (Ctrl+C).")
|
||||
sys.exit(0)
|
||||
|
||||
# List of the tags that are a status or alert
|
||||
on_event_tags = [
|
||||
"1365",
|
||||
"AC_Insulation_Status",
|
||||
"ACSw_Status",
|
||||
"ActErrNo1",
|
||||
"ActErrNo10",
|
||||
"ActErrNo2",
|
||||
"ActErrNo3",
|
||||
"ActErrNo4",
|
||||
"ActErrNo5",
|
||||
"ActErrNo6",
|
||||
"ActErrNo7",
|
||||
"ActErrNo8",
|
||||
"ActErrNo9",
|
||||
"BESS_Control_Mode",
|
||||
"BESS_Control_Mode_2",
|
||||
"Calibration_Required",
|
||||
"CO_Sensor_1",
|
||||
"CO_Sensor_2",
|
||||
"CO_Sensor_3",
|
||||
"CO_Sensor_4",
|
||||
"CO_Sensor_5",
|
||||
"Combi_Detector_1",
|
||||
"Combi_Detector_2",
|
||||
"Combi_Detector_3",
|
||||
"Combi_Detector_4",
|
||||
"Combi_Detector_5",
|
||||
"Combi_Detector_6",
|
||||
"DC_Insulation_Status",
|
||||
"DCSw_1_Status",
|
||||
"DCSw_2_Status",
|
||||
"DCSw_3_Status",
|
||||
"Digital_Input_Line_0",
|
||||
"DIL0",
|
||||
"DIL1",
|
||||
"DIL2",
|
||||
"Door_Open",
|
||||
"EMS_Control",
|
||||
"Energy_Fault",
|
||||
"ESS_Status",
|
||||
"Extinguisher_Activated",
|
||||
"Fault_Id_tmp",
|
||||
"Fault_Module_Id",
|
||||
"Fault_Status",
|
||||
"General_Fault",
|
||||
"InvSt_tmp",
|
||||
"Last_Event",
|
||||
"Loss_of_Agent",
|
||||
"Manual_mode",
|
||||
"Manual_Pull_Station",
|
||||
"MV_Transformer_Gas_Monitoring",
|
||||
"MV_Transformer_Oil_Level_Trip",
|
||||
"MV_Transformer_Pressure",
|
||||
"MV_Transformer_Pressure_Trip",
|
||||
"MV_Transformer_Temperature_Alarm",
|
||||
"MV_Transformer_Temperature_Warning",
|
||||
"NbModule",
|
||||
"NbModule_Run",
|
||||
"Reg_Request",
|
||||
"Version",
|
||||
"Warn_Id"
|
||||
]
|
||||
|
||||
|
||||
try:
|
||||
for device in devices:
|
||||
|
||||
print(f"{device.getSite()} {device.getNumber()} {device.getDeviceId()}")
|
||||
|
||||
modbus_tags_to_set_on_event = {}
|
||||
id_on_event_topic = -1
|
||||
id_12h_topic = -1
|
||||
|
||||
current_device_modules = registry_manager.get_modules(device.deviceId)
|
||||
for module in current_device_modules:
|
||||
if (module.module_id == module_id):
|
||||
device.setModule(module)
|
||||
|
||||
# This block get all the Modbus tags available and cross check them with the list of tags that require changes
|
||||
payload = '{"method":"GET", "path":"/tags/list"}'
|
||||
try:
|
||||
direct_method = CloudToDeviceMethod(method_name=method_name, payload=json.loads(payload))
|
||||
response = registry_manager.invoke_device_module_method(device_id=device.deviceId, module_id=module_id, direct_method_request=direct_method)
|
||||
device_tags = json.dumps(response.payload, indent = 2)
|
||||
parsed_tags = json.loads(device_tags)
|
||||
|
||||
for item in parsed_tags['data']:
|
||||
if item['prvdName'] == "modbus_tcp_master" and item['tagName'] in on_event_tags:
|
||||
modbus_tags_to_set_on_event.setdefault(item['srcName'], []).append(item['tagName'])
|
||||
|
||||
except Exception as e:
|
||||
logger.error(f"Exception when getting list of device's Modbus tags that can be set On Event:\n{str(e)}")
|
||||
|
||||
|
||||
payload = '{"method":"GET", "path":"/azure-iotedge/messages"}'
|
||||
try:
|
||||
direct_method = CloudToDeviceMethod(method_name=method_name, payload=json.loads(payload))
|
||||
response = registry_manager.invoke_device_module_method(device_id=device.deviceId, module_id=module_id, direct_method_request=direct_method)
|
||||
device_topics = json.dumps(response.payload, indent = 2)
|
||||
parsed_topics = json.loads(device_topics)
|
||||
|
||||
for item in parsed_topics["data"]:
|
||||
if item['enable'] and item["outputTopic"] == "REL_OE_PCS":
|
||||
id_on_event_topic = item['id']
|
||||
if item['enable'] and item["outputTopic"] == "REL_OE_PCS_12H":
|
||||
id_12h_topic = item['id']
|
||||
|
||||
available_topics = [
|
||||
item for item in parsed_topics["data"]
|
||||
if item['enable']
|
||||
and item['id'] != id_on_event_topic
|
||||
and item['id'] != id_12h_topic
|
||||
]
|
||||
|
||||
if id_on_event_topic == -1:
|
||||
id_on_event_topic = resolve_missing_topic("REL_OE_PCS", available_topics)
|
||||
|
||||
if id_12h_topic == -1:
|
||||
id_12h_topic = resolve_missing_topic("REL_OE_PCS_12H", available_topics)
|
||||
|
||||
|
||||
targets = [
|
||||
{"id": id_on_event_topic, "name": "OnEvent"},
|
||||
{"id": id_12h_topic, "name": "12h"}
|
||||
]
|
||||
|
||||
for target in targets:
|
||||
target_id = target["id"]
|
||||
target_name = target["name"]
|
||||
|
||||
if target_id > 0:
|
||||
topic_item = next((item for item in parsed_topics["data"] if item["id"] == target_id), None)
|
||||
if topic_item:
|
||||
original_tags = topic_item.get("tags", {}).get("modbus_tcp_master", {})
|
||||
else: # Pure error handling, detected ID does not exist
|
||||
print(f"Error: ID {target_id} not found. Skipping.")
|
||||
continue
|
||||
else: # Not error handling, target_id == 0 means creation of new topic
|
||||
original_tags = {}
|
||||
|
||||
final_tag_list = copy.deepcopy(original_tags)
|
||||
for device_name, tags_to_add in modbus_tags_to_set_on_event.items():
|
||||
if device_name not in final_tag_list:
|
||||
final_tag_list[device_name] = []
|
||||
current_list = final_tag_list[device_name]
|
||||
for tag in tags_to_add:
|
||||
if tag not in current_list:
|
||||
current_list.append(tag)
|
||||
# CASE A: CREATE NEW
|
||||
if target_id == 0:
|
||||
print(f"[{target_name}] ID is 0 -> ACTION: CREATE NEW TOPIC")
|
||||
elif final_tag_list != original_tags:
|
||||
print(f"[{target_name}] ID {target_id} -> ACTION: UPDATE EXISTING")
|
||||
else:
|
||||
print(f"[{target_name}] ID {target_id} -> ACTION: NONE (Already up to date)")
|
||||
|
||||
# Removing tags from existing topics: cleaned_topic
|
||||
protected_ids = [id_on_event_topic, id_12h_topic]
|
||||
|
||||
|
||||
for item in parsed_topics["data"]:
|
||||
if item['id'] in protected_ids or item['enable'] == False:
|
||||
continue
|
||||
|
||||
original_tags = item.get("tags", {}).get("modbus_tcp_master", {})
|
||||
|
||||
try:
|
||||
idAsset = re.search(r"idAsset\s*:\s*\((.*?)\)", item.get("format", "")).group(1).strip()
|
||||
except Exception as e:
|
||||
print(f"Exception while getting idAsset: {item}")
|
||||
continue
|
||||
|
||||
if not original_tags:
|
||||
continue
|
||||
|
||||
final_tag_list = copy.deepcopy(original_tags)
|
||||
modification_needed = False
|
||||
|
||||
for device_name, tags_to_remove in modbus_tags_to_set_on_event.items():
|
||||
|
||||
if device_name in final_tag_list:
|
||||
current_list = final_tag_list[device_name]
|
||||
new_list = [t for t in current_list if t not in tags_to_remove]
|
||||
|
||||
if len(new_list) != len(current_list):
|
||||
final_tag_list[device_name] = new_list
|
||||
modification_needed = True
|
||||
|
||||
if not final_tag_list[device_name]:
|
||||
del final_tag_list[device_name]
|
||||
|
||||
if modification_needed:
|
||||
print(f"-> Applying update for topic: {item['outputTopic']} (ID: {item['id']} & {idAsset})")
|
||||
|
||||
except Exception as e:
|
||||
logger.error(f"Exception when getting all Telemetry Topics:\n{str(e)}")
|
||||
|
||||
user_input = 'Y' # input("Continue? Y/n ").lower().strip()
|
||||
if user_input == 'n':
|
||||
print("Stopping loop.")
|
||||
break
|
||||
except KeyboardInterrupt:
|
||||
# This block runs when user presses Ctrl+C
|
||||
print("\nProgram killed by user (Ctrl+C).")
|
||||
sys.exit(0)
|
||||
|
||||
|
||||